Find the message or code shown in Results. These guides explain existing simulator checks; they do not certify electrical safety or replace professional review.

16 guides found

Solar panels & MPPT

PV voltage exceeds the MPPT limit

The modeled open-circuit voltage of a PV string exceeds the connected controller's maximum PV input voltage.

Read guide: PV voltage exceeds the MPPT limit

Diagnostic codes

MPPT_PV_OVER_VOLTAGE

Why SolCircuit displays it

SolCircuit compares each string's calculated open-circuit voltage with the MPPT specification stored for the selected product version.

What to inspect

The panels in the affected string, their series connections, and the MPPT maximum PV open-circuit voltage.

What to review next

Review the selected specifications and modeled arrangement, then run the simulation again after any change. This check does not apply cold-weather corrections or electrical-code design margins; obtain professional review before installation.

Solar panels & MPPT

PV current exceeds the MPPT limit

The modeled PV array short-circuit current exceeds the controller's maximum PV input-current rating.

Read guide: PV current exceeds the MPPT limit

Diagnostic codes

MPPT_PV_OVER_CURRENT

Why SolCircuit displays it

The engine compares aggregated array short-circuit current with the stored PV input-current limit, not the controller's battery-side charge-current rating.

What to inspect

The affected array's parallel strings and the MPPT PV input-current specification.

What to review next

Review the arrangement and exact product specifications before rerunning. The check does not include code multipliers or environmental adjustments and does not establish charging performance.

Solar panels & MPPT

Mixed panel characteristics

Panels in an array have different modeled electrical characteristics, or parallel strings have different maximum-power voltages.

Read guide: Mixed panel characteristics

Diagnostic codes

PV_PANEL_MISMATCH

Why SolCircuit displays it

The engine compares rated power, voltage and current characteristics and string maximum-power voltages. Differences are advisory; different product names alone do not trigger this warning.

What to inspect

The selected panel specifications and the series or parallel arrangement within the affected array.

What to review next

Review the approximation shown in Results: series voltages add with limiting current, while parallel currents add. Unequal branch voltages have no single modeled operating voltage. No full current-voltage curves, shading, bypass diodes or mismatch-loss percentage is modeled. Warning-only, complete evaluations can be Yellow; independent electrical errors still take priority.

Solar panels & MPPT

PV wiring cannot be fully evaluated

SolCircuit cannot resolve a supported PV arrangement to a single MPPT input, or a panel is not connected to an MPPT.

Read guide: PV wiring cannot be fully evaluated

Diagnostic codes

PV_TOPOLOGY_AMBIGUOUSPV_PANEL_NOT_CONNECTED_TO_MPPTPV_ARRAY_MULTIPLE_MPPT_TARGETS

Why SolCircuit displays it

PV calculations need a resolved connection path. Ambiguous paths and an array reaching multiple controllers cannot be treated as a successful check.

What to inspect

The affected panels, both connection paths, and the MPPT PV input terminals.

What to review next

Review missing or conflicting connections in the modeled graph. Rerun after correcting the arrangement; an unavailable result is not a compatibility pass.

Connections & wiring

A direct connection has reversed polarity

An otherwise supported direct DC connection joins opposite polarities where they are not allowed.

Read guide: A direct connection has reversed polarity

Diagnostic codes

REVERSED_POLARITY

Why SolCircuit displays it

The terminal check detects positive-to-negative polarity on supported DC relationships. The supported panel-to-panel series connection is an explicit exception.

What to inspect

The positive and negative terminal labels on the highlighted connection and the component roles at each end.

What to review next

Review the intended modeled connection before changing it. Do not assume every positive-to-negative panel series link is an error. This guide is not an instruction to rewire live equipment.

Connections & wiring

The connected terminals are incompatible

A direct link joins terminal roles or electrical domains that the simulator does not support together.

Read guide: The connected terminals are incompatible

Diagnostic codes

INCOMPATIBLE_TERMINAL_ROLESELECTRICAL_DOMAIN_MISMATCH

Why SolCircuit displays it

The runtime checks the terminal domain first, then its supported role relationship. A connector being visible does not mean any other connector is compatible with it.

What to inspect

The terminal labels and component categories on both ends, including PV inputs, battery connections, inverter inputs and AC load connections.

What to review next

Review the intended connection against the available terminal roles. Correct the modeled connection and rerun rather than treating the link as a valid power path.

Connections & wiring

The project connection structure is invalid

The project contains a missing endpoint, duplicate identity or connection, a terminal ownership mismatch, or a terminal connected to itself.

Read guide: The project connection structure is invalid

Diagnostic codes

DUPLICATE_COMPONENT_IDDUPLICATE_TERMINAL_IDDUPLICATE_CONNECTION_IDTERMINAL_OWNER_MISMATCHCONNECTION_TERMINAL_NOT_FOUNDSELF_CONNECTIONDUPLICATE_CONNECTION

Why SolCircuit displays it

The structural gate checks graph integrity before electrical evaluation. It blocks simulation instead of calculating from an invalid structure.

What to inspect

The connection or component identified by Results, particularly missing endpoints and repeated links.

What to review next

Review affected items in Builder. If the structure cannot be corrected using normal editing, use the existing support path with the displayed code; do not manually alter stored project identifiers.

Batteries & inverters

Battery voltage is not supported by the MPPT

The battery's modeled nominal voltage is not in the connected MPPT's supported battery-system voltage list.

Read guide: Battery voltage is not supported by the MPPT

Diagnostic codes

MPPT_BATTERY_VOLTAGE_UNSUPPORTED

Why SolCircuit displays it

The check uses exact membership in the stored supported-voltage list.

What to inspect

The selected battery nominal voltage, MPPT supported battery voltages, and the connection between them.

What to review next

Verify the chosen product versions and their manufacturer documentation. This check does not evaluate battery chemistry, charging profiles or battery banks.

Batteries & inverters

Battery voltage does not match the inverter

The connected battery and inverter do not have the same modeled nominal DC voltage.

Read guide: Battery voltage does not match the inverter

Diagnostic codes

BATTERY_INVERTER_VOLTAGE_UNSUPPORTED

Why SolCircuit displays it

The engine compares their stored nominal voltages by exact equality, without inventing a tolerance or battery-bank model.

What to inspect

The battery nominal voltage, inverter nominal DC input voltage, and the affected DC connection.

What to review next

Review the exact specifications and modeled pairing, then rerun any changed configuration. Matching nominal voltage alone does not establish installation safety.

Appliances & loads

Inverter continuous load is exceeded

The connected operating load exceeds the inverter's modeled continuous output-power rating.

Read guide: Inverter continuous load is exceeded

Diagnostic codes

INVERTER_CONTINUOUS_OVERLOAD

Why SolCircuit displays it

The engine compares the connected operating-power total, including applicable load quantities and overrides, with the stored inverter rating.

What to inspect

The connected appliances, quantities, operating-power overrides and inverter continuous output specification.

What to review next

Review whether the modeled loads and specifications represent the intended configuration. Update incorrect inputs and rerun; the model does not infer real-world usage schedules.

Appliances & loads

Inverter surge load is exceeded

The connected potential surge load exceeds the inverter's modeled surge output-power rating.

Read guide: Inverter surge load is exceeded

Diagnostic codes

INVERTER_SURGE_OVERLOAD

Why SolCircuit displays it

The engine compares the modeled potential surge total with the selected inverter's stored surge rating.

What to inspect

Appliance surge specifications or overrides, quantities, and the inverter surge output rating.

What to review next

Review the modeled load inputs and rerun after changes. The check does not model startup timing, surge duration or load diversity.

Batteries & inverters

Battery discharge-current capability is exceeded

The modeled continuous DC current demanded by the inverter exceeds the connected battery's continuous discharge-current rating.

Read guide: Battery discharge-current capability is exceeded

Diagnostic codes

BATTERY_CONTINUOUS_DISCHARGE_OVER_CURRENT

Why SolCircuit displays it

The engine uses connected operating load, inverter efficiency and nominal DC voltage to obtain the current demand for this comparison.

What to inspect

The connected loads, inverter specifications and battery maximum continuous discharge-current specification.

What to review next

Verify the modeled configuration and stored specifications, then rerun changes. This is not a surge-current, BMS-trip, cable-sizing or fuse-sizing check.

Connections & wiring

A battery or load path is ambiguous

The engine cannot resolve a supported relationship for the affected battery, controller, inverter or load check.

Read guide: A battery or load path is ambiguous

Diagnostic codes

MPPT_BATTERY_TOPOLOGY_AMBIGUOUSBATTERY_INVERTER_TOPOLOGY_AMBIGUOUSLOAD_INVERTER_TOPOLOGY_AMBIGUOUSBATTERY_DISCHARGE_CURRENT_TOPOLOGY_AMBIGUOUS

Why SolCircuit displays it

These checks need supported, unambiguous connection paths. Missing or competing paths cannot be replaced with guessed relationships.

What to inspect

The components identified by the diagnostic and their complete connection paths.

What to review next

Review the modeled links and supported arrangement. Do not interpret a skipped or unavailable check as evidence that those components are compatible.

Simulation results

A required specification is missing or invalid

An affected calculation lacks a usable input. This is an evaluation limitation, not automatically an electrical incompatibility.

Read guide: A required specification is missing or invalid

Diagnostic codes

PV_INVALID_PANEL_SPECIFICATIONMPPT_INVALID_VOLTAGE_SPECIFICATIONMPPT_INVALID_CURRENT_SPECIFICATIONINVALID_BATTERY_VOLTAGE_SPECIFICATIONINVALID_MPPT_BATTERY_VOLTAGE_SPECIFICATIONINVALID_INVERTER_VOLTAGE_SPECIFICATIONINVALID_APPLIANCE_LOAD_SPECIFICATIONINVALID_APPLIANCE_OVERRIDEINVALID_INVERTER_CONTINUOUS_POWER_SPECIFICATIONINVALID_INVERTER_SURGE_POWER_SPECIFICATIONINVALID_INVERTER_EFFICIENCY_SPECIFICATIONINVALID_INVERTER_NOMINAL_DC_VOLTAGE_SPECIFICATIONINVALID_BATTERY_CONTINUOUS_DISCHARGE_CURRENT_SPECIFICATIONMISSING_BATTERY_NOMINAL_CAPACITYINVALID_BATTERY_NOMINAL_CAPACITYMISSING_BATTERY_USABLE_ENERGYINVALID_BATTERY_USABLE_CAPACITYINVALID_BATTERY_DEPTH_OF_DISCHARGE

Why SolCircuit displays it

Individual checks reject missing, non-finite or otherwise invalid values according to their own input rules. Battery runtime also needs usable capacity or energy information.

What to inspect

The component and input named by the diagnostic, including appliance overrides or battery capacity information where relevant.

What to review next

Correct an invalid editable input using verified information. For a stored product-specification problem, report the product and diagnostic through support. Do not invent a value to make the check pass.

Simulation results

Blocked, partial or unavailable results

A blocked simulation cannot pass the structural gate. A partial run has an incomplete component chain or unresolved applicable evaluation. Compatibility may be unavailable when required checks cannot finish.

Read guide: Blocked, partial or unavailable results

Why SolCircuit displays it

The engine keeps evaluation completeness separate from electrical compatibility. Known electrical errors can still produce Red even when other checks are incomplete.

What to inspect

The current Results diagnostics and the affected component or connection paths.

What to review next

Resolve the reported issues and rerun. Green means compatible only within modeled checks and stored specifications; Yellow means a complete evaluable result with warnings and no errors; Red means an electrical error was found. None of these states certifies a physical installation.

Simulation results

Results are stale or have not been run

Results belong to the project revision that was simulated. Electrical edits can make a previous result stale; a new project may have no result yet.

Read guide: Results are stale or have not been run

Why SolCircuit displays it

Builder tracks the simulation revision separately from the current project revision and does not silently rerun the full simulation for every edit.

What to inspect

The current Results status and the changes made since the last simulation.

What to review next

Run the simulation for the current configuration before relying on the displayed result. A previous Green result does not establish compatibility for an edited configuration.

Getting started

What can I build with SolCircuit?

Basic supports Small House projects. Pro supports Small, Medium and Large House projects. Plan a solar configuration using panels, MPPT controllers, batteries, inverters, appliance loads and grounding components. Arrange components in roof and interior views, connect terminals, and review compatibility.

How does the simulation work?

Run Simulation calculates results from the components and connections in your configuration using deterministic electrical rules. Electrical edits require another run. Green means compatible within the checks performed, Yellow requires review, and Red identifies incompatible conditions.

Does SolCircuit replace a solar professional?

No. It is a planning and educational tool, not engineering certification, code approval, or site-specific installation verification. Follow local electrical requirements and seek qualified professional review.

Projects

How many configurations can I save?

Basic includes up to 2 saved configurations; Pro includes 10. Use Save Project to save an immutable revision. Unsaved Builder changes are not automatically saved.

What happens to my Projects if Pro ends?

You receive 60 days of post-Pro Basic access. If you have more than two Projects, choose two active Basic Projects; the others remain retained and read-only. After that fallback window, current access is read-only. Projects are not automatically deleted.

BOM

Is BOM included with Pro?

Yes. Basic users can instead purchase a 5 days BOM Pass for $6.99.

Can Basic users generate a BOM?

Yes, with an active 5 days (120-hour) BOM Pass. BOM generation uses an exact saved revision. Green and Yellow results allow CSV export, with warnings for Yellow; Red or incomplete results are blocked. Email delivery requires the transactional email service to be configured.

Billing

What happens if I cancel Pro?

Pro remains available through the paid-through date. After Pro expires, the existing post-Pro Basic access and Project-selection rules apply.

How do temporary feature passes work?

A BOM Pass grants account-level BOM access for 5 days (120 hours). Access is rechecked when used and ends when the pass expires or is revoked. A temporary pass does not upgrade your account to Pro or grant Priority support.

Account

Where can I see my plan and feature access?

Open My Account to see your plan, saved configuration usage, subscription state and feature-access expiration. Support replies use your authenticated account email.

Support & feedback

Still need help?

Use the existing support form below. Check the service notice above for current email availability.